CONTEC Logo
产品信息 技术支持 文件下载 新消息 产品型录 联系我们 公司简介 返回主页

Excel Scope - MS Excel-based Measure Software

Excel Scope is a data acquisition software which enables direct importing of measure data from CONEC analog-to-digital converter to MS Excel. This software supports data acquisition as well as data analysis and report making using Excel spreadsheet functions.

For instance, Excel Scope allows you to make an inspection report after acquiring data by utilizing Excel macro functions. Like this, you can easily establish a measure system that meets your own needs.
Please note that changing of macro is to be conducted on your responsibility.

This DAC software allows you to simulate data acquisition without requiring an analog-to-digital converter.
Try out its basic features before purchasing the hardware.
(API-PAC(WDM) software driver for the demo board must be installed on your PC.)

 

 index
Excel Measure System Setup / Operation
  Description   Details of measure setup
  Basic configuration of Excel measure system   Details of line setup
  Specifications   Details of graph setup
  Required environment   Details of range setup
Downloading Excel Scope   Details of calculation setup
  Downloading Excel Scope   Details of monitor function
Setup / Operation Introduction / Procedures
  Screen operation   Introduction / Operation procedures
  Report function Contact address:
  Details of device setup   Contact address
 

Excel Scope can acquire maximum 32-channel data from CONTEC analogue input board or from PC card at a high speed, and can display them in graphs or write them onto Excel sheet. It also allows you to set up trigger function, continuous execution and real-time calculation as well as to output the measure result as a report.

  • Excel Scope is highly suited for use in an environment which involves high-speed monitoring. It has already been used in the following applications:
         Measurement of acceleration, strain and oscillation

  • Excel Scope is a program which has been developed by combining ACX-PAC(W32) components. Purchasing ACX-PAC(W32) along with Excel2000(or Excel2002 or Exce2003) allows you to modify and customize the program to suit your needs.

configuration of measure system

 You can select a system configuration that optimally meets the desired application and the analysis environment.
 For the evaluation samples of our data acquisition products, please contact our sales department.

configuration of measure system

5返回目录

dot_line
Specifications
spec table

5返回目录

Required environment

Excel 2000, 2002 or 2003
Precision of measure: Approx.±1.5mV at ±10V range
(This is when using a signal source which incorporates a high-speed operational amplifier. When the ambient temperature is either 0°C or 50°C, there may be an error of 0.1% with the maximum range.)
The maximum sampling speed will vary depending on the PC CPU, memory and hard disk performance.

Downloading Excel Scope
For Windows XP/2000/Me/98 download (Version: 4.0   Data capacity: 3,436KB   Last updated: 2005/02/18)
Screen operation

Screen operation

(1) Read / Save files
(2) Exit program
(3) Details of device setup 
 Details of measure setup
 Details of line setup
Details of graph setup
 Details of range setup
(4)

 Details of calculation setup

(5)  Details of monitor function
(6) Display Help sheet
(7) Start / Stop execution
(8) Expanding / Reducing / Moving the display area
 Expanding: Fixed (Twice), Expands the area enclosed by a mouse., Expands the area according to the specified zoom.
 Reducing: Fixed (Half), Reduces the area according to the specified zoom., Reduces the area back to its original size.
 Moving: Moves the display using a mouse or a scroll bar.
(9)

Display cursor in the data area
 Cursor type: Plumb, Horizon, Cross
 Calculates the data touched by a cursor.

(10) Execution status
  Enable continuous execution / Specify the zoom
(11)

Measure information
  Display board name / Channel / Period / Points / Calculation / Trigger

(12) Data display area
(13) Data list
  Display the data of each channel
(14) Report function
(15) List of data acquisition / Setup information
(16) Display Help sheet
 
Report function
   
This function creates the following report automatically.

 

Details of device setup
   
Select the board or PC card to be used. If it is not displayed in the list, check that the hardware is installed properly. (Refer to the manual and FAQ.)  FAQ

 


Details of measure setup
   
Set the trigger (level trigger, pretrigger), sampling period and measure points.

 

Details of line setup

   
Set the lines for graphical representation. (Channel No., thickness, symbols, calculation)
 

 

 

Details of graph setup
   
Set the Y axis, scale color, background color and grid color for graphical representation.
 

 

 

Details of range setup
   

Set the hardware range and graph axis Y.

 

 

 

Details of calculation
   

Scaling, smoothing, absolute, square root, differentiation and integration are supported as real-time calculation.
The calculation will be conducted for the checked item in the graph setting.

 

 

Details of monitor function
   

Maximum, minimum and average values for each line are displayed.

 

 

Introduction / Operation procedures
 

When using either PCI or Low Profile PCI board

1) Set the board ID. (See the hardware manual for the details.)
When mounting more than one board of the same type on one PC unit, you need to differentiate each board by allocating a board ID.
2) After confirming that PC power is off, insert the board onto PCI bus slot.
 

When using PC card

1) Connect the cable to PC card.
2) Insert it onto CardBus slot. (See the hardware manual for the details.)
 
¢­
1) Connect the connector portion of the board or PC card to the connector portion of the terminal block with a cable.
2) Connect the terminal block to the probe.
¢­
A driver software must be installed to let each OS recognize the hardware.
The latest version of the driver software API-AIO(WDM) can be downloaded from the download page.
API-TOOL
The required software is execution environment (runtime).
Install the driver that matches your OS.
For the details of the installation procedure, download the online HELP.
¢­
1) Downloading the software
  Download measure software (Excel Scope).
2) Executing the downloaded file
  Execute the downloaded file (Excel_System_xx). When the installation program is automatically started, proceed with the installation by following the instruction.
3) Starting the program
  When the installation is complete, "Contec PC Measure" will be created in the Start Menu program. Execute "Excel Measure System (Excel Scope)" you can find inside "Contec PC Measure".
¢­
The basic operation procedure is as described in the following. See Excel Scope HELP for the setup details.
1) Registering the hardware
  Select the board or PC card to be used.
2) Setting the measure information
  Specify the trigger, sampling period and measure points.
3) Setting the graph
  Set the lines for graphical representation. (Channel No., color, thickness, symbols, calculation)
4) Setting the range
  Specify the hardware range and graph axis Y range.
5) Click the Start button and execute.
6) Once the data is acquired, use Excel to process it.
 
Contact address:

 

   For further inquiries concerning Excel Scope, please contact us at the following e-mail address:

E-mail: tsc@contec.com.cn